Multifocal intraocular lenses in cataract surgery: literature review of benefits and side effects (2013)

by N de Vries, R Nuijts
Venue:J. Cataract Refr. Surg
Add To MetaCart

Tools

Sorted by:
Results 1 - 2 of 2

Energy efficiency of a new trifocal intraocular lens F. Vega

by unknown authors
"... The light distribution among the far, intermediate and near foci of a new trifocal intraocular lens (IOL) is experimentally determined, as a function of the pupil size, from image analysis. The concept of focus energy efficiency is introduced because, in addition to the theoretical diffraction effic ..."
Abstract - Add to MetaCart
The light distribution among the far, intermediate and near foci of a new trifocal intraocular lens (IOL) is experimentally determined, as a function of the pupil size, from image analysis. The concept of focus energy efficiency is introduced because, in addition to the theoretical diffraction efficiency of the focus, it accounts for other factors that are naturally presented in the human eye such as the level of spherical aberration (SA) upon the IOL, light scattering at the diffractive steps or the depth of focus. The trifocal IOL is tested in-vitro in two eye models: the aberration-free ISO model, and a so called modified-ISO one that uses an artificial cornea with positive spherical SA in instead. The SA upon the IOL is measured with a Hartmann-Shack sensor and compared to the values of theoretical eye models. The results show, for large pupils, a notorious reduction of the energy efficiency of the far and near foci of the trifocal IOL due to two facts: the level of SA upon the IOL is larger than the value the lens is able to compensate for and there is significant light scattering at the diffractive steps. On the other hand, the energy efficiency of the intermediate focus for small pupils is enhanced by the contribution of the extended depth of focus of the near and far foci. Thus, while IOLs manufacturers tend to provide just the theoretical diffraction efficiency of the foci to show which would be the performance of the lens in terms of light distribution among the foci, our results put into evidence that this is better described by using the energy efficiency of the foci.
(Show Context)

Citation Context

...N Increasing patient demand of spectacle independence after cataract surgery or clear lens extraction has been an extraordinary incentive for the development of multifocal intraocular lenses (MIOLs). =-=[1]-=- Diffracted-based MIOLs have shown better optical performance than either, their counterparts refractive MIOLs or accommodating IOLs. [2, 3] Until very recently, diffractive MIOLs available in the mar...

Research Article Vignetting and Field of View with the KAMRA Corneal Inlay

by Achim Langenbucher, Susanne Goebels, Nóra Szentmáry, Berthold Seitz , 2013
"... Copyright © 2013 Achim Langenbucher et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Purpose. To evaluate the effect of the KAM ..."
Abstract - Add to MetaCart
Copyright © 2013 Achim Langenbucher et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Purpose. To evaluate the effect of the KAMRA corneal inlay on the retinal image brightness in the peripheral visual field.Methods. A KAMRA inlay was “implanted ” into a theoretical eye model in a corneal depth of 200 microns. Corneal radius was varied to a steep, normal, and flat (7.37, 7.77, and 8.17mm) version keeping the proportion of anterior to posterior radius constant. Pupil size was varied from 2.0 to 5.0mm. Image brightness was determined for field angles from −70 ∘ to 70 ∘ with and without KAMRA and proportion of light attenuation was recorded. Results. In our parameter space, the attenuation in brightness ranges in between 0 and 60%. The attenuation in brightness is not affected by corneal shape. For large field angles where the incident ray bundle is passing through the peripheral cornea, brightness is not affected. For combinations of small pupil sizes (2.0 and 2.5mm) and field angles of 20–40∘, up to 60 % of light may be blocked with the KAMRA. Conclusion. For combinations of pupil sizes and field angles, the attenuation of image brightness reaches levels up to 60%. Our theoretical findings have to be clinically validated with detailed investigation of this vignetting effect. 1.
(Show Context)

Citation Context

... recover accommodation in progressed age, and many attempts have been made to develop active or passive lens implants (such as accommodating lenses) [1–6], refractive or diffractive multifocal lenses =-=[7]-=-, customized photorefractive keratectomy (PRK) or Laser in situ keratomileusis (LASIK) ablations using the excimer laser generating sectorial or zonal near focus region in the cornea [8–11], or changi...