Results 1 - 10
of
15,478
Profiling with Optical Transition Radiation
- Proceedings of 1993 Particle Accelerator Conference
, 1993
"... One of the simplest applications of optical transition radiation (OTR) to accelerator beam diagnostics is beam profiling. We compare the limits of resolution of beam profiles made using OTR and profiles made using synchrotron radiation. We will discuss the physical basis for the limiting resolution ..."
Abstract
-
Cited by 2 (0 self)
- Add to MetaCart
One of the simplest applications of optical transition radiation (OTR) to accelerator beam diagnostics is beam profiling. We compare the limits of resolution of beam profiles made using OTR and profiles made using synchrotron radiation. We will discuss the physical basis for the limiting resolution
BEAM EMITTANCE DETERMINATION USING OPTICAL TRANSITION RADIATION
, 1139
"... Optical transition radiation produced by an electron beam, with an energy scaling from 80 keV to 20 MeV, on alu-minium and silver foils, has been observed in backward direction. Count rates of photons were measured for three orders of magnitude of the electron energy. Emittance has been determined a ..."
Abstract
- Add to MetaCart
Optical transition radiation produced by an electron beam, with an energy scaling from 80 keV to 20 MeV, on alu-minium and silver foils, has been observed in backward direction. Count rates of photons were measured for three orders of magnitude of the electron energy. Emittance has been determined
MULTI OPTICAL TRANSITION RADIATION SYSTEM FOR ATF2 ∗
"... In this paper we describe the design, installation and first calibration tests of a Multi Optical Transition Radiation System in the beam diagnostic section of the Extraction (EXT) line of ATF2, close to the multi wire scanner system. This system will be a valuable tool for measuring beam sizes and ..."
Abstract
- Add to MetaCart
In this paper we describe the design, installation and first calibration tests of a Multi Optical Transition Radiation System in the beam diagnostic section of the Extraction (EXT) line of ATF2, close to the multi wire scanner system. This system will be a valuable tool for measuring beam sizes
OPTICAL TRANSITION RADIATION MEASUREMENTS ON THE BEIJING FREE-ELECTRON LASER*
"... The measurement system have been developed for use with the Beijing free-electron laser (BFEL), based on the techniques of optical transition radiation (OTR). The 32-channel OTR detector forms part of a high-resolution (0.02%) electron spectrometer. Design parts of the spectrometer are presented, an ..."
Abstract
- Add to MetaCart
The measurement system have been developed for use with the Beijing free-electron laser (BFEL), based on the techniques of optical transition radiation (OTR). The 32-channel OTR detector forms part of a high-resolution (0.02%) electron spectrometer. Design parts of the spectrometer are presented
Optical Transition Radiation Monitor for the T2K Experiment
"... An Optical Transition Radiation monitor has been developed for the proton beam-line of the T2K long base-line neutrino oscillation experiment. The monitor operates in the highly radioactive environment in proximity to the T2K target. It uses optical transition radiation, the light emitted from a thi ..."
Abstract
- Add to MetaCart
An Optical Transition Radiation monitor has been developed for the proton beam-line of the T2K long base-line neutrino oscillation experiment. The monitor operates in the highly radioactive environment in proximity to the T2K target. It uses optical transition radiation, the light emitted from a
SLAC-PUB-13395 OBSERVATION OF COHERENT OPTICAL TRANSITION RADIATION IN THE LCLS LINAC ∗
, 2008
"... The beam diagnostics in the linac for the Linac Coherent Light Source (LCLS) X-ray FEL project at SLAC includes optical transition radiation (OTR) screens for measurements of transverse and longitudinal beam properties. We report on observations of coherent light emission from the OTR screens (COTR) ..."
Abstract
- Add to MetaCart
The beam diagnostics in the linac for the Linac Coherent Light Source (LCLS) X-ray FEL project at SLAC includes optical transition radiation (OTR) screens for measurements of transverse and longitudinal beam properties. We report on observations of coherent light emission from the OTR screens (COTR
Resolution of Transverse Electron Beam Measurements Using Optical Transition Radiation
, 2005
"... In the plasma wakefield acceleration experiment E-167, optical transition radiation is used to measure the transverse profile of the electron bunches before and after the plasma acceleration. The distribution of the electric field from a single electron does not give a point-like distribution on the ..."
Abstract
-
Cited by 1 (0 self)
- Add to MetaCart
In the plasma wakefield acceleration experiment E-167, optical transition radiation is used to measure the transverse profile of the electron bunches before and after the plasma acceleration. The distribution of the electric field from a single electron does not give a point-like distribution
BEAM PROFILE MEASUREMENT AT 30 GEV USING OPTICAL TRANSITION RADIATION ∗
"... We present results of measurements of spot size and angular divergence of a 30 GeV electron beam though use of optical transition radiation (OTR). The OTR near field pattern and far field distribution are measured as a function of beam spot size and divergence at wavelengths of 441, 532, and 800 nm, ..."
Abstract
- Add to MetaCart
We present results of measurements of spot size and angular divergence of a 30 GeV electron beam though use of optical transition radiation (OTR). The OTR near field pattern and far field distribution are measured as a function of beam spot size and divergence at wavelengths of 441, 532, and 800 nm
1Test of an Optical Transition Radiation Detector at the CERN-SPS1
"... We are considering the use of Optical Transition Radiation (OTR) Detectors to measure the energy spectrum of high-energy primary cosmic rays (about and above 1000 TeV) in outer space. A very preliminary prototype of such ``calorimeter’ ’ was tested at the CERN-SPS H2 test beam-line using electrons o ..."
Abstract
- Add to MetaCart
We are considering the use of Optical Transition Radiation (OTR) Detectors to measure the energy spectrum of high-energy primary cosmic rays (about and above 1000 TeV) in outer space. A very preliminary prototype of such ``calorimeter’ ’ was tested at the CERN-SPS H2 test beam-line using electrons
Results 1 - 10
of
15,478