Results 1 - 10
of
39
Mutual-information-based registration of medical images: a survey
- IEEE Transcations on Medical Imaging
, 2003
"... Abstract—An overview is presented of the medical image processing literature on mutual-information-based registration. The aim of the survey is threefold: an introduction for those new to the field, an overview for those working in the field, and a reference for those searching for literature on a s ..."
Abstract
-
Cited by 109 (0 self)
- Add to MetaCart
Abstract—An overview is presented of the medical image processing literature on mutual-information-based registration. The aim of the survey is threefold: an introduction for those new to the field, an overview for those working in the field, and a reference for those searching for literature on a specific application. Methods are classified according to the different aspects of mutual-information-based registration. The main division is in aspects of the methodology and of the application. The part on methodology describes choices made on facets such as preprocessing of images, gray value interpolation, optimization, adaptations to the mutual information measure, and different types of geometrical transformations. The part on applications is a reference of the literature available on different modalities, on interpatient registration and on different anatomical objects. Comparison studies including mutual information are also considered. The paper starts with a description of entropy and mutual information and it closes with a discussion on past achievements and some future challenges. Index Terms—Image registration, literature survey, matching, mutual information. I.
Fast parametric elastic image registration
- IEEE Transactions on Image Processing
, 2003
"... Abstract—We present an algorithm for fast elastic multidimensional intensity-based image registration with a parametric model of the deformation. It is fully automatic in its default mode of operation. In the case of hard real-world problems, it is capable of accepting expert hints in the form of so ..."
Abstract
-
Cited by 40 (3 self)
- Add to MetaCart
Abstract—We present an algorithm for fast elastic multidimensional intensity-based image registration with a parametric model of the deformation. It is fully automatic in its default mode of operation. In the case of hard real-world problems, it is capable of accepting expert hints in the form of soft landmark constraints. Much fewer landmarks are needed and the results are far superior compared to pure landmark registration. Particular attention has been paid to the factors influencing the speed of this algorithm. The B-spline deformation model is shown to be computationally more efficient than other alternatives. The algorithm has been successfully used for several two-dimensional (2-D) and three-dimensional (3-D) registration tasks in the medical domain, involving MRI, SPECT, CT, and ultrasound image modalities. We also present experiments in a controlled environment, permitting an exact evaluation of the registration accuracy. Test deformations are generated automatically using a random hierarchical fractional wavelet-based generator. Index Terms—Elastic registration, image registration, landmarks, splines. I.
An Approach to Multimodal Biomedical Image Registration Utilizing Particle Swarm Optimization
- IEEE Transactions on Evolutionary Computation
, 2004
"... Biomedical image registration, or geometric alignment of two-dimensional and/or three-dimensional (3-D) image data, is becoming increasingly important in diagnosis, treatment planning, functional studies, computer-guided therapies, and in biomedical research. Registration based on intensity values u ..."
Abstract
-
Cited by 19 (0 self)
- Add to MetaCart
Biomedical image registration, or geometric alignment of two-dimensional and/or three-dimensional (3-D) image data, is becoming increasingly important in diagnosis, treatment planning, functional studies, computer-guided therapies, and in biomedical research. Registration based on intensity values usually requires optimization of some similarity metric between the images. Local optimization techniques frequently fail because functions of these metrics with respect to transformation parameters are generally nonconvex and irregular and, therefore, global methods are often required. In this paper, a new evolutionary approach, particle swarm optimization, is adapted for single-slice 3-D-to-3-D biomedical image registration. A new hybrid particle swarm technique is proposed that incorporates initial user guidance. Multimodal registrations with initial orientations far from the ground truth were performed on three volumes from different modalities. Results of optimizing the normalized mutual information similarity metric were compared with various evolutionary strategies. The hybrid particle swarm technique produced more accurate registrations than the evolutionary strategies in many cases, with comparable convergence. These results demonstrate that particle swarm approaches, along with evolutionary techniques and local methods, are useful in image registration, and emphasize the need for hybrid approaches for difficult registration problems.
Registration of Challenging Image Pairs: Initialization, Estimation, and Decision
, 2007
"... Our goal is an automated 2D-image-pair registration algorithm capable of aligning images taken of a wide variety of natural and man-made scenes as well as many medical images. The algorithm should handle low overlap, substantial orientation and scale differences, large illumination variations, and p ..."
Abstract
-
Cited by 15 (4 self)
- Add to MetaCart
Our goal is an automated 2D-image-pair registration algorithm capable of aligning images taken of a wide variety of natural and man-made scenes as well as many medical images. The algorithm should handle low overlap, substantial orientation and scale differences, large illumination variations, and physical changes in the scene. An important component of this is the ability to automatically reject pairs that have no overlap or have too many differences to be aligned well. We propose a complete algorithm including techniques for initialization, for estimating transformation parameters, and for automatically deciding if an estimate is correct. Keypoints extracted and matched between images are used to generate initial similarity transform estimates, each accurate over a small region. These initial estimates are rank-ordered and tested individually in succession. Each estimate is refined using the Dual-Bootstrap ICP algorithm, driven by matching of multiscale features. A three-part decision criteria, combining measurements of alignment accuracy, stability in the estimate, and consistency in the constraints, determines whether the refined transformation estimate is accepted as correct. Experimental results on a data set of 22 challenging image pairs show that the algorithm effectively aligns 19 of the 22 pairs and rejects 99.8 percent of the misalignments that occur when all possible pairs are tried. The algorithm substantially out-performs algorithms based on keypoint matching alone.
Gradient-based 2-D/3-D rigid registration of fluoroscopic X-ray to CT
- IEEE Trans. Med. Imag
, 2003
"... Abstract—We present a gradient-based method for rigid registration of a patient preoperative computed tomography (CT) to its intraoperative situation with a few fluoroscopic X-ray images obtained with a tracked C-arm. The method is noninvasive, anatomybased, requires simple user interaction, and inc ..."
Abstract
-
Cited by 14 (0 self)
- Add to MetaCart
Abstract—We present a gradient-based method for rigid registration of a patient preoperative computed tomography (CT) to its intraoperative situation with a few fluoroscopic X-ray images obtained with a tracked C-arm. The method is noninvasive, anatomybased, requires simple user interaction, and includes validation. It is generic and easily customizable for a variety of routine clinical uses in orthopaedic surgery. Gradient-based registration consists of three steps: 1) initial pose estimation; 2) coarse geometry-based registration on bone contours, and; 3) fine gradient projection registration (GPR) on edge pixels. It optimizes speed, accuracy, and robustness. Its novelty resides in using volume gradients to eliminate outliers and foreign objects in the fluoroscopic X-ray images, in speeding up computation, and in achieving higher accuracy. It overcomes the drawbacks of intensity-based methods, which are slow and have a limited convergence range, and of geometry-based methods, which depend on the image segmentation quality. Our simulated, in vitro, and cadaver experiments on a human pelvis CT, dry vertebra, dry femur, fresh lamb hip, and human pelvis under realistic conditions show a mean 0.5–1.7 mm (0.5–2.6 mm maximum) target registration accuracy. Index Terms—Fluoroscopic X-ray to CT registration, gradient based, image registration, 2D/3D rigid registration. I.
Intensity gradient based registration and fusion of multi-modal images
- Methods of Information in Medicine, Schattauer Verlag
, 2006
"... multi-modal images ..."
Motion Correction Algorithms May Create Spurious Brain Activations in the Absence of Subject Motion
- NeuroImage
, 2001
"... This paper describes several experiments that prove that standard motion correction methods may induce spurious activations in some motion-free fMRI studies. This artifact stems from the fact that activated areas behave like biasing outliers for the difference of square-based measures usually drivin ..."
Abstract
-
Cited by 9 (2 self)
- Add to MetaCart
This paper describes several experiments that prove that standard motion correction methods may induce spurious activations in some motion-free fMRI studies. This artifact stems from the fact that activated areas behave like biasing outliers for the difference of square-based measures usually driving such registration methods. This effect is demonstrated first using a motion-free simulated time series including artificial activation-like signal changes. Several additional simulations explore the influence of activation amplitude and extent. The effect is finally highlighted on an actual time series obtained from a 3-T magnet. All the experiments are performed using four different realignment methods, which allows us to show that the problem may be overcome by methods based on a robust similarity measure like mutual information. 2001 Academic Press Key Words: fMRI; motion correction; artifact; spurious activation; robust registration
Automatic 3D Registration of Lung Surfaces in Computed Tomography Scans
- in Proceedings of the 4th Int Conf on Medical Image Computing and Computer-Assisted Intervention (MICCAI
, 2001
"... Abstract. We developed an automated system that registers chest CT images temporally. Our registration method matches corresponding anatomical landmarks to obtain initial registration parameters. The initial point-to-point registration is then generalized to an iterative surface-tosurface registrati ..."
Abstract
-
Cited by 7 (0 self)
- Add to MetaCart
Abstract. We developed an automated system that registers chest CT images temporally. Our registration method matches corresponding anatomical landmarks to obtain initial registration parameters. The initial point-to-point registration is then generalized to an iterative surface-tosurface registration method. Our “goodness-of-fit ” measure is evaluated at each step in the iterative scheme until the registration performance is sufficient. We applied our method to register the 3D lung surfaces of 10 pairs of chest CT scans and report a promising registration performance. 1 1
High dimensional normalized mutual information for image registration using random lines
- In International Workshop on Medical Image Registration
, 2006
"... Abstract. Mutual information has been successfully used as an effective similarity measure for multimodal image registration. However, a drawback of the standard mutual information-based computation is that the joint histogram is only calculated from the correspondence between individual voxels in t ..."
Abstract
-
Cited by 6 (0 self)
- Add to MetaCart
Abstract. Mutual information has been successfully used as an effective similarity measure for multimodal image registration. However, a drawback of the standard mutual information-based computation is that the joint histogram is only calculated from the correspondence between individual voxels in the two images. In this paper, the normalized mutual information measure is extended to consider the correspondence between voxel blocks in multimodal rigid registration. The ambiguity and highdimensionality that appears when dealing with the voxel neighborhood is solved using uniformly distributed random lines and reducing the number of bins of the images. Experimental results show a significant improvement with respect to the standard normalized mutual information. 1
Non-rigid MR/US registration for tracking brain deformations
- In IEEE Computer Society Press, editor, Proc of Int. Workshop on Medical Imaging and Augmented Reality (MIAR 2001), 10-12 June 2001, Shatin, Hong Kong
, 2001
"... During a neuro-surgical intervention, the brain tissues shift and warp. In order to keep an accurate positioning of the surgical instruments, one has to estimate this deformation from intra-operative images. 3D ultrasound (US) imaging is an innovative and low-cost modality which appears to be suited ..."
Abstract
-
Cited by 5 (4 self)
- Add to MetaCart
During a neuro-surgical intervention, the brain tissues shift and warp. In order to keep an accurate positioning of the surgical instruments, one has to estimate this deformation from intra-operative images. 3D ultrasound (US) imaging is an innovative and low-cost modality which appears to be suited for such computer-assisted surgery tools. In this paper, we present a new image-based technique to register intra-operative 3D US with pre-operative Magnetic Resonance (MR) data. A first automatic rigid registration is achieved by the maximisation of a similarity measure that generalises the correlation ratio. Then, brain deformations are tracked in the 3D US time-sequence using a “demon’s” like algorithm. Experiments show that a registration accuracy of the MR voxel size is achieved for the rigid part, and a qualitative accuracy of a few millimetres could be obtained for the complete tracking system. 1.