Results 1 -
9 of
9
eye during acute hyperglycemia
"... Purpose To measure the refractive properties of the healthy human eye during acute hyperglycemia by means of Scheimpflug imaging and Hartmann-Shack aberrometry. Methods Acute hyperglycemia was induced in five healthy subjects (two males, three females, mean age ±SD 24.8 years ± 4.6) by means of an o ..."
Abstract
- Add to MetaCart
Purpose To measure the refractive properties of the healthy human eye during acute hyperglycemia by means of Scheimpflug imaging and Hartmann-Shack aberrometry. Methods Acute hyperglycemia was induced in five healthy subjects (two males, three females, mean age ±SD 24.8 years ± 4.6) by means
RESEARCH ARTICLE Effect of Intraocular Forward Scattering and Corneal Higher-Order Aberrations on Visual Acuity after Descemet’s Stripping Automated
, 1371
"... Purpose To assess the relationship of intraocular forward scattering and corneal higher-order aberra-tions (HOAs) with best spectacle corrected visual acuity (BSCVA) after Descemet’s strip-ping automated endothelial keratoplasty (DSAEK), and to compare these parameters between DSAEK and non-Descemet ..."
Abstract
- Add to MetaCart
was 71.7 ± 10.4 years. We quantitatively evaluated the objective scattering index (OSI) using the double-pass instrument (OQAS II, Visiometrics) and corneal HOAs using Hartmann-Shack aberrometry (KR-9000PW, Topcon) 3 months postoperatively. Results The mean OSI, corneal HOAs, and logMAR BSCVA 3 months
ABERROMETRY: BASIC SCIENCE AND CLINICAL APPLICATIONS
"... This paper addresses the concept, measurement and applications of wave aberrations. The ocular optics is not perfect. Apart from conventional low order aberrations (such as defocus and astigmatism) retinal im-ages are degraded by other high order aberrations. Aberrometers typically measure ray devia ..."
Abstract
- Add to MetaCart
the Hartmann-Shack wavefront sensor, laser ray tracing, spatially resolved refractometer or the corneal aberrations. This technology has been used to advance our understanding on several visual mechanisms, ocular conditions, and corrective methods. Applications include accommodation, myopia, aging, myopia
Testretest reliability of clinical Shack-Hartmann measurements
, 2004
"... PURPOSE. To evaluate the stability of clinical monochromatic aberrometry measurements over a wide range of time scales. METHODS. Monochromatic aberrations in four normal eyes were measured with a clinical Shack-Hartmann aberrometer. A chin rest or a supplemental bite bar attachment was used to stabi ..."
Abstract
-
Cited by 3 (0 self)
- Add to MetaCart
PURPOSE. To evaluate the stability of clinical monochromatic aberrometry measurements over a wide range of time scales. METHODS. Monochromatic aberrations in four normal eyes were measured with a clinical Shack-Hartmann aberrometer. A chin rest or a supplemental bite bar attachment was used
On-eye Evaluation of Optical Performance of Rigid and Soft Contact Lenses
"... A Shack-Hartmann aberrometer was used to assess the optical performances of eyes corrected with rigid or soft contact lenses compared to spectacles. Metrics of optical quality derived from the measured wave aberrations were consistent with the subjective rating by subjects of visual clarity. Further ..."
Abstract
-
Cited by 3 (0 self)
- Add to MetaCart
A Shack-Hartmann aberrometer was used to assess the optical performances of eyes corrected with rigid or soft contact lenses compared to spectacles. Metrics of optical quality derived from the measured wave aberrations were consistent with the subjective rating by subjects of visual clarity
Vision-realistic rendering: simulation of the scanned foveal image from wavefront data of human subjects
- in: First Symposium on Applied Perception in Graphics and Visualization, colocated with ACM SIGGRAPH
"... We introduce the concept of vision-realistic rendering – the computer generation of synthetic images that incorporate the characteristics of a particular individual’s entire optical system. Specifically, this paper develops a method for simulating the scanned foveal image from wavefront data of actu ..."
Abstract
-
Cited by 20 (5 self)
- Add to MetaCart
of actual human subjects, and demonstrates those methods on sample images. First, a subject’s optical system is measured by a Shack-Hartmann wavefront aberrometry device. This device outputs a measured wavefront which is sampled to calculate an object space point spread function (OSPSF). The OSPSF
1 and 0.14 mm, Z4
"... 3 and 0.11 mm. The mean total higher-order RMS was 0.33 mm. CONCLUSIONS: There was a general consensus for the magnitude of HOAs expected in normal adult human eyes. At least 90 % of the sample had aberrations less than double the mean values reported here. These values can serve as a set of referen ..."
Abstract
- Add to MetaCart
of reference norms. J Cataract Refract Surg 2006; 32:2064–2074 Q 2006 ASCRS and ESCRS Shack-Hartmann aberrometry is the most popular method for measuring monochromatic higher-order aberrations (HOAs) of the eye. It provides objective, accurate,1–6 high-resolution data needed for wavefront-guided correc
Abstract Introducing Vision-Realistic Rendering
"... We introduce the concept of vision-realistic rendering–the generation of images that incorporate characteristics of a particular individual’s optical system. We then describe a pipeline for creating vision-realistic images. First, a subject’s optical system is measured by a Shack-Hartmann wavefront ..."
Abstract
- Add to MetaCart
We introduce the concept of vision-realistic rendering–the generation of images that incorporate characteristics of a particular individual’s optical system. We then describe a pipeline for creating vision-realistic images. First, a subject’s optical system is measured by a Shack-Hartmann wavefront
Visual Psychophysics and Physiological Optics Higher Order Aberrations in Children with Down Syndrome
"... PURPOSE. Down syndrome (DS) is associated with ocular abnormalities and reduced visual function. Studies report atypical optical structures in the DS eye such as thinner, steeper corneae and thinner crystalline lenses and, functionally, a degrading influence of the optics on acuity. This study furt ..."
Abstract
- Add to MetaCart
cycloplegia using Shack-Hartmann aberrometry. HOAs were analyzed over a 3-mm and 5-mm pupil using Zernike polynomials from third-sixth order. Optical quality was explored using Visual Strehl ratios (VSX) and equivalent defocus values. RESULTS. HOAs were measured successfully from 68% of the DS group and 95