See this document in CiteSeerX!

Deformable Models for Volume Feature Tracking (1999)  (Make Corrections)  (3 citations)
Gregory James Klein



  Home/Search   Context   Related

 
View or download:
lbl.gov/~klein/gjkthesis.pdf
Cached:  PS.gz  PS  PDF   Image  Update  Help

From:  lbl.gov/~klein/ (more)
(Enter author homepages)

Rate this article: (best)
  Comment on this article  
(Enter summary)

Abstract: Deformable Models for Volume Feature Tracking by Gregory James Klein Doctor of Philosophy in Vision Science University of California, Berkeley Professor Jitendra Malik, Chair Conventional three dimensional medical imaging devices have made possible the routine visualization of biological tissue acquired as a sequence of image volumes over time. Because biological tissue is rarely static, the accurate registration of features in two volumes from an image sequence is a common requirement... (Update)

Context of citations to this paper:   More

...current total motion field and the process is repeated. Further details on the overall motion estimation technique may be found in [5] [6]. Note that the linear approximation used in the Taylor series approach assumes that the maximum norm of is relatively small, else the...

.... is an extension of our previous 3D algorithm which uses a non uniform regularization function inspired from elastic material models [26,27]. The goal of the algorithm is to find a dense Lagrangian vector field describing the motion of each voxel between a source volume and a...

Cited by:   More
Variational Based Analysis and Modelling using B-splines - Sherar (2004)   (Correct)
Four-Dimensional Processing of Deformable Cardiac PET Data - Gregory Klein Center (2002)   (Correct)
Elastic Material Model Mismatch Effects in Deformable Motion.. - Klein, Huesman   (Correct)

Active bibliography (related documents):   More   All
1.5:   Bibliography on Image Registration - Nielsen (2004)   (Correct)
1.2:   Definition of a 4D continuous planispheric.. - Declerck, Feldmar.. (1998)   (Correct)
1.1:   Forward Deformation of PET Volumes Using Non-Uniform.. - Gregory Klein Lawrence (1999)   (Correct)

Similar documents based on text:   More   All
0.4:   Heterogeneous Acoustic Environments for Multi-stream Automatic.. - Shire   (Correct)
0.3:   Modeling and Rendering Architecture From Photographs - Debevec (1996)   (Correct)
0.2:   MCAT - A Multimedia Cardiac Angiogram Tool - Cheng, Banerjea, Pol, Lundstrom   (Correct)

Related documents from co-citation:   More   All
2:   velocity fields from 3-d cine ct images of the human heart (context) - Song, Leahy et al. - 1991
2:   Robot Vision (context) - Horn - 1986
2:   Forward deformation of PET volumes using non-uniform elastic material constraint.. - Klein - 1999

BibTeX entry:   (Update)

G. J. Klein. Deformable models for volume feature tracking. Report LBNL-43257, Lawrence Berkeley National Laboratory, 1999. (Ph.D. Thesis). http://citeseer.ist.psu.edu/klein99deformable.html   More

@misc{ klein99deformable,
  author = "G. Klein",
  title = "Deformable models for volume feature tracking",
  text = "G. J. Klein. Deformable models for volume feature tracking. Report LBNL-43257,
    Lawrence Berkeley National Laboratory, 1999. (Ph.D. Thesis).",
  year = "1999",
  url = "citeseer.ist.psu.edu/klein99deformable.html" }
Citations (may not include all citations):
1386   Snakes: Active contour models (context) - Kass, Witkin et al. - 1988
755   Determining optical flow (context) - Horn, Schunck - 1981
695   Robot Vision (context) - Horn - 1986
359   Scale space filtering (context) - Witkin - 1983
193   Principal warps: Thin-plate splines and the decomposition of.. (context) - Bookstein - 1989
190   The structure of images (context) - Koenderink - 1984
182   Finite-element methods for active contour models and balloon.. - Cohen, Cohen - 1993
174   Multiresolution elastic matching (context) - Bajcsy, Kovacic - 1989
105   An investigation of smoothness constraints for the estimatio.. (context) - Nagel, Enkelmann - 1986
99   Recovery of nonrigid motion and structure (context) - Pentland, Horowitz - 1991
73   Structural image restoration through deformable templates (context) - Amit, Grenander et al. - 1991
61   A Treatise on the Mathematical Theory of Elasticity (context) - Love - 1927
49   Constraints on deformable models: Recovering 3D shape and no.. (context) - Terzopoulos, Witken et al. - 1988
38   Image registration based on boundary mapping - Davatzikos, Prince et al. - 1996
35   Motion estimation from tagged MR image sequences (context) - Prince, McVeigh - 1992
34   Human heart: Tagging with MR imaging - a method for noninvas.. (context) - Zerhouni, Parish et al. - 1988
27   A surface-based technique for warping threedimensional image.. (context) - Thompson, Toga - 1996
25   Shape and the information in medical images: A decade of the.. (context) - Bookstein - 1997
24   Optimal Registration of Deformed Images (context) - Broit - 1981
24   Individualizing neuroanatomical atlases using a massively pa.. (context) - Christensen, Miller et al. - 1996
23   Accurate three-dimensional registration of CT, PET and/or MR.. (context) - Pelizzari, Chen et al. - 1989
21   Evaluation of ridge seeking operators for multimodality medi.. (context) - Maintz, van den Elsen et al. - 1996
20   MR imaging of motion with spatial modulation of magnetizatio.. (context) - Axel, Dougherty - 1989
19   Bending and stretching models for lv wall motion analysis fr.. (context) - Amini, Duncan - 1992
18   3d brain mapping using a deformable neuroanatomy (context) - Christensen, Rabbitt et al. - 1994
18   Inferring surface trace and differential structure from 3-D .. (context) - Sandor, Zucker - 1990
18   Tracking and motion analysis of the left ventricle with defo.. - Bardinet, Cohen et al. - 1996
16   Elastically deforming a 3D atlas to match anatomical brain i.. (context) - Gee, Reivich et al. - 1993
16   Mathematical model of geometry and fibrous structure of the .. (context) - Nielsen, Le Grice et al. - 1991
15   Variational Methods in Elasticity and Plasticity (context) - Washizu - 1982
15   Demonstration of accuracy and clinical versatility of mutual.. (context) - Meyer, Boes et al. - 1996
14   Large elastic deformations of isotropic materials (context) - Rivlin - 1948
14   Automated image registration: I. general methods and intrasu.. (context) - Woods, Grafton et al. - 1998
13   Three-dimensional motion and deformation of the heart wall: .. (context) - Young, Axel - 1992
13   A stereotactic method of anatomical localization for positro.. (context) - Fox, Perlmutter et al. - 1985
12   The use of three- and four-dimensional surface harmonics for.. (context) - Matheny, Goldgof - 1995
12   Phase contrast cine magnetic resonance imaging (context) - Pelc, Herfkens et al. - 1991
12   Spatial registration and normalization of images (context) - Friston, Ashburner et al. - 1995
12   Curvature-based approach to point correspondence recovery in.. (context) - Kambhamettu, Goldgof - 1994
10   Automated image registration: II. intersubject validation of.. (context) - Woods, Grafton et al. - 1998
10   The Numerical Solution of Ordinary and Partial Differential .. (context) - Sewell - 1988
10   Spatial normalization of 3D brain images using deformable mo.. (context) - Davatzikos - 1996
10   A fast scalable algorithm for discontinuous optical flow est.. (context) - Ghosal, Vanek - 1996
10   The existence of geometrical density-image transformations c.. (context) - Fitzpatrick - 1988
10   Threedimensional myocardial deformations: Calculation with d.. (context) - O'Dell, Moore et al. - 1995
9   Determining cardiac velocity fields and intraventricular pre.. (context) - Song, Leahy et al. - 1994
9   Development and evaluation of tracking algorithms for cardia.. (context) - Constable, Rath et al. - 1994
7   Fast non-rigid matching of 3d medical images (context) - Thirion - 1995
7   Computing the differential characteristics of isointensity s.. (context) - Thirion, Gourdon - 1995
7   Transmural myocardial deformation in the canine left ventric.. (context) - Waldman, Fung et al. - 1985
6   Evaluation of right and left ventricular volume and ejection.. (context) - Pretorius, Xia et al. - 1997
6   Deformable b-solids and implicit snakes for localization and.. - Radeva, Amini et al. - 1996
6   Estimation of three-dimensional cardiac velocity fields: Ass.. (context) - Gorce, Friboulet et al. - 1997
5   Quantification of and correction for left ventricular systol.. (context) - Rogers, Shapiro et al. - 1991
5   Co-planar Stereotactic Atlas of the Human Brain: 3Dimensiona.. (context) - Talairach, Tournoux - 1988
5   Evaluation of elastic matching system for anatomic (CT, MR) .. (context) - Dann, Hoford et al. - 1989
5   Accuracy and precision of the computerized brain atlas progr.. (context) - Seitz, Bohm et al. - 1990
5   An Introduction to the Theory of Elasticity (context) - Atkin, Fox - 1980
4   Computation of 3-D velocity fields from 3-D cine CT images o.. (context) - Song, Leahy - 1991
4   A computerized brain atlas: Construction, anatomical content.. (context) - Greitz, Bohm et al. - 1991
4   Geometrically deformable templates for shape-based segmentat.. - Rueckert, Burger - 1997
4   Regional three-dimensional geometry and function of left ven.. (context) - Lessick, Sideman et al. - 1991
4   A three-dimensional finite element method for large elastic .. (context) - Costa, Hunter et al. - 1996
4   Kriging: A method of interpolation for geographical informat.. (context) - Oliver, Webster - 1990
4   A three-dimensional finite element method for large elastic .. (context) - Costa, Hunter et al. - 1996
4   Coupled B-Snake grids and constrained thin-plate splines for.. - Amini, Chen et al. - 1998
4   Transformations and algorithms in a computerized brain atlas (context) - Thurfjell, Bohm et al. - 1993
4   Stereotactic PET atlas of the human brain: Aid for visual in.. (context) - Minoshima, Koeppe et al. - 1994
4   Automatic retrieval of anatomical structures in 3D medical i.. (context) - Declerck, Subsol et al. - 1995
3   Tracking myocardial deformation using phase contrast MR velo.. - Meyer, Constable et al.
3   Kinematics of the beating heart (context) - Meyer, Ziskin et al. - 1980
3   Modeling, analysis, and visualization of left ventricle shap.. (context) - Chen, Huang et al. - 1994
3   A physics-based coordinate transformation for 3-D image matc.. (context) - Davis, Khotanzad et al. - 1997
3   Mechanics of Continuous Media (context) - Hunter - 1976
3   Computational electromechanics of the heart (context) - Hunter, Nash et al. - 1997
3   Three-dimensional elastic matching of volumes (context) - Moshfeghi, Ranganath et al. - 1994
2   A three-dimensional mathematical phantom of the human torso .. (context) - Terry, Tsui et al. - 1990
2   Implementation and validation of a fully automatic system fo.. (context) - Andersson, Thurfjell - 1997
2   The ECAT EXACT HR: Performance of a new high resolution posi.. (context) - Weinhard, Dahlbom et al. - 1994
2   Definition of a 4D continuous polar transformation for the t.. (context) - Declerck, Feldmar et al. - 1996
2   Anatomic standardization: Linear scaling and nonlinear warpi.. (context) - Minoshima, Koeppe et al. - 1994
2   A 3D optical flow approach to addition of deformable PET vol.. (context) - Klein, Huesman - 1997
2   Forward deformation of PET volumes using material constraint.. (context) - Klein - 1998
2   Plastic transformation of PET images (context) - Friston, Frith et al. - 1991
1   Users manual: Donner algorithms for reconstruction tomograph.. (context) - Huesman, Gullberg et al. - 1977
1   Prospectively gated cardiac computed tomography (context) - Moore, Judy et al. - 1983
1   Dynamic 3D modles with local and global deformations: Deform.. (context) - Terzopoulos, Metaxas - 1991
1   Single right ventricles compared with systemic right ventric.. (context) - Fogel, Weinberg et al. - 1995
1   Mechanics of the single left ventricle: A study in ventricul.. (context) - Fogel, Weinberg et al. - 1998
1   Quantitative measurement of left ventricular volumes in man .. (context) - Vine, Dodge et al. - 1997
1   Restospective cardiac gating: A review of technical aspects .. (context) - Lenz, Haacke et al. - 1989
1   Regional and temporal nonuniformity of shape and wall moveme.. (context) - Barletta, Baroni et al. - 1998
1   Constitutive relastions and finite deformations of passive c.. (context) - Humphrey, Yin - 1989
1   List mode data acquisition for retrospective respiratory-car.. (context) - Huesman, Klein et al. - 1998
1   Regional left ventricular wall motion abnormalities in idiop.. (context) - Sunnerhagen, Bhargava et al. - 1990
1   Real-time system for respiratory-cardiac gating in positron .. (context) - Klein, Reutter et al. - 1997
1   Nonuniformity of inner and outer systolic wall thickening in.. (context) - Gallagher, Osakada et al. - 1985
1   Automatic 3D intersubject recgistration of MR volumetric dat.. (context) - Collins, Neelin et al. - 1994
1   Boundary finding with parametrically deformed models (context) - Staib, Duncan - 1992
1   Cardiac gating of transmission data is unnecessary for atten.. (context) - Klein, Reutter et al. - 1998
1   Acquisition and automated 3-D segmentation of respiratory/ca.. (context) - Reutter, Klein et al. - 1996

Documents on the same site (http://imasun.lbl.gov/~klein/):   More
Elastic Material Model Mismatch Effects in Deformable Motion.. - Klein, Huesman   (Correct)
Four-Dimensional Processing of Deformable Cardiac PET Data - Gregory Klein Center (2002)   (Correct)
Forward Deformation of PET Volumes Using Non-Uniform.. - Gregory Klein Lawrence (1999)   (Correct)

Online articles have much greater impact   More about CiteSeer.IST   Add search form to your site   Submit documents   Feedback  

CiteSeer.IST - Copyright Penn State and NEC