See this document in CiteSeerX!

Effects of Attenuation and Blurring in Cardiac SPECT and Compensations Using Parallel Computers (1995)  (Make Corrections)  
Edward V. R. Di Bella



  Home/Search   Context   Related

Links:   ACM

 
View or download:
utah.edu/mirl/dibella/pap...thesis.ps.Z
Cached:  PS.gz  PS  PDF   Image  Update  Help

From:  utah.edu/mirl/dibella/pape...list (more)
(Enter author homepages)

Rate this article: (best)
  Comment on this article  
(Enter summary)

Abstract: ce. Andy Barclay and Tsannhui Chu provided a wealth of knowledge about the computer systems and software at Crawford Long. I have especially benefitted from long conversations with Andy. His comments have much improved this thesis. I thank the Stevensons for being so much help at critical junctures: the start and the end. I gratefully acknowledge funding from a Georgia Tech teaching assistantship, the Georgia affiliate of the American Heart Association, and the Emory/Georgia Tech Biomedical... (Update)

Active bibliography (related documents):   More   All
1.5:   Attenuation Artifacts in SPECT: Effect of "Wrap-Around" Lung in.. - Di Bella   (Correct)
0.8:   Parallel Computation for Positron Emission Tomography with.. - Olesen (1996)   (Correct)
0.7:   Performance Modeling of Optical Interconnection.. - Cruz-Rivera..   (Correct)

Similar documents based on text:   More   All
0.3:   Compensations as Signaling Devices in the Political Economy .. - Castro, Coen-Pirani   (Correct)
0.2:   Automatic Segmentation Of 3d Cardiac Spect Imagery - Mullick, Ezquerra   (Correct)
0.2:   A Hierarchical Feature Based Deformation Model Applied to.. - Jacob Laading Colin (1998)   (Correct)

BibTeX entry:   (Update)

@misc{ bella-effects,
  author = "Edward V. R. Di Bella",
  title = "Effects of Attenuation and Blurring in Cardiac SPECT and Compensations
    Using Parallel Computers",
  url = "citeseer.ist.psu.edu/bella95effect.html" }
Citations (may not include all citations):
1535   Cambridge University Press (context) - Press, Flannery et al. - 1991
654   Fundamentals of Digital Image Processing (context) - Jain - 1989  ACM
171   Advanced Computer Architecture: Parallelism (context) - Hwang - 1993
144   PVM: Parallel Virtual Machine - Geist, Beguelin et al. - 1994  ACM
128   Two--Dimensional Signal and Image Processing (context) - Lim - 1990
127   Digital Image Restoration (context) - Andrews, Hunt - 1977  ACM
115   Maximum likelihood reconstruction for emission tomography - Shepp, Vardi - 1982
115   Multidimensional Digital Signal Processing (context) - Dudgeon, Mersereau - 1984  ACM
95   Principles of Computerized Tomographic Imaging (context) - Kak, Slaney - 1988  ACM
88   EM reconstruction algorithms for emission and transmission t.. (context) - Lange, Carson - 1984
60   A statistical model for positron emission tomography (context) - Vardi, Shepp et al. - 1985
59   The Radon Transform and Some of its Applications (context) - Deans - 1983
36   A Maximum a posteriori probability expectation maximization .. (context) - Levitan, Herman - 1987
33   Iterative methods for image deblurring (context) - Biemond, Lagendijk et al. - 1990
28   Image reconstruction by parametric cubic convolution (context) - Park, Schowengerdt - 1983
26   Preconditioning methods for improved convergence rates in it.. (context) - Clinthorne, Pan et al. - 1993
24   The use of sieves to stabilize images produced with the EM a.. (context) - Snyder, Miller - 1985
20   A fast algorithm for general raster rotation (context) - Paeth - 1986  ACM
20   Quantitation in positron emission computed tomography: 1. ef.. (context) - Hoffman, Huang et al. - 1979
19   Noise and edge artifacts in maximumlikelihood reconstruction.. (context) - Snyder, Miller - 1987
14   CA: IEEE Computer Society Press (context) - Wolberg, Warping et al. - 1990
14   Bayesian image reconstruction for emission tomography incorp.. (context) - Miller, Roysam - 1991
12   Maximum likelihood SPECT in clinical computation times using.. (context) - McCarthy, Miller - 1991
12   A rotation method for raster image using skew transformation (context) - Tanaka, Kameyama et al. - 1986
11   Maximum a posteriori estimation for SPECT using regularizati.. (context) - Butler, Miller - 1993
10   Complete exchange and broadcast algorithms for meshes (context) - Takkella, Seidel - 1994
9   Convergence criteria for iterative restoration methods (context) - Trussell - 1983
8   Bayesian and related methods in image reconstruction from in.. (context) - Hanson - 1987
8   Parallelization of the EM algorithm for 3-D PET image recons.. (context) - Chen, Lee et al. - 1991
8   A method for attenuation correction in radionuclide computed.. (context) - Chang - 1978
7   Clinically important characteristics of maximumlikelihood re.. (context) - Miller, Wallis - 1992
5   Parallelized formulation of the maximum likelihood-expectati.. (context) - Cruz-Rivera, Di Bella et al. - 1995
5   On parallelizing the EM algorithm for PET image reconstructi.. (context) - Chen, Lee - 1994  ACM   DBLP
5   Practical tradeoffs between noise, quantitation, and number .. (context) - Liow, Strother - 1991
5   Parallelized formulation of the maximum likelihood-expectati.. (context) - Cruz-Rivera, Di Bella et al. - 1995
5   Complete exchange in 2D meshes (context) - Sundar, Jayasimha et al. - 1994
5   An evaluation of maximum likelihood reconstruction for SPECT (context) - Chornoboy, Chen et al. - 1990
4   Results of a clinical receiver operating characteristic stud.. (context) - Llacer - 1993
4   Phantom study of breast tissue attenuation in myocardial ima.. (context) - Manglos, Thomas et al. - 1993
4   A Wiener filter for nuclear medicine images (context) - King, Doherty et al. - 1991
3   Comparison between ML-EM and WLS-CG algorithms for SPECT ima.. (context) - Tsui - 1991
3   The GEM MAP algorithm with 3-D SPECT system response (context) - Hebert, Gopal - 1992
3   A three-dimensional high-throughput architecture using throu.. (context) - Wills - 1995
3   Quantitative cardiac SPECT reconstruction with reduced image.. (context) - Tsui, Zhao et al. - 1994
3   Parallel simulated annealing for emission tomography (context) - Girodias, Barrett et al. - 1991
3   Optimal specificity of thallium-201 SPECT through recognitio.. (context) - DePuey, Garcia - 1989
3   Study of reprojection methods in terms of their resolution l.. (context) - Yu, Huang - 1993
3   High--speed computation of the radon transform and backproje.. (context) - Shieh, Current et al. - 1992
3   Iterative algorithms for corrections to proximity effects in.. (context) - Rau - 1995
3   A fast and stable weighted-least-squares MAP conjugate-gradi.. (context) - Lalush, Tsui - 1993
3   MLE reconstruction of a brain phantom using a monte carlo tr.. (context) - Veklerov, Llacer - 1988
2   Errors in reprojection methods in computerized tomography (context) - Trussell, Orun-Ozturk et al. - 1987
2   A study of the liver-heart artifact in emission tomography (context) - Nuyts, Dupont et al. - 1995
2   Three-dimensional iterative reconstruction algorithms with a.. (context) - Zeng, Gullberg et al. - 1991
2   Attenuation and detector response compensations used with gi.. (context) - Lalush, Tsui - 1991
2   Analysis of emission tomographic scan data: limitations impo.. (context) - Kessler, Ellis et al. - 1984
2   Introduction (context) - Katsaggelos - 1991  ACM   DBLP
2   3D maximum a posteriori estimation for single photon emissio.. (context) - Miller, Butler - 1993
2   Avoidance of additional aliasing in multipass image rotation.. (context) - Fraser, Schowengerdt - 1994
2   Attenuation cause and effect relationships in cardiac SPECT .. (context) - Nowak - 1993
2   The feasibility of images reconstructed with the method of s.. (context) - Veklerov, Llacer - 1990
2   Correction of nonuniform attenuation in cardiac SPECT imagin.. (context) - Tsui, Gullberg et al. - 1989
1   3D SPECT simulations of a complex 3-D mathematical brain mod.. (context) - Kim, Zeeburg et al. - 1992
1   Computer simulation study of false myocardial perfusion defe.. (context) - Di Bella, Boyers et al. - 1993
1   Effects of changes in myocardial wall thickening on ECG gate.. (context) - Eisner, Schmarkey et al. - 1993
1   Comparison of rotation-based projectors for iterative recons.. (context) - Di Bella, Barclay et al. - 1995
1   Experimentally determining a parametric model for the point .. (context) - Hebert, Murphy et al. - 1991
1   Positron computed tomography: Instrumentation (context) - Muehllehner, Colsher - 1982
1   Evaluation of corrective reconstruction methods using a 3D c.. (context) - Zhao, Tsui et al. - 1993
1   Inhomogeneity of gated and ungated SPECT technetium-99m-sest.. (context) - Eisner, Martin et al. - 1993
1   High speed computation of the EM algorithm for PET image rec.. (context) - Rajan, Patnaik et al. - 1994
1   Comparison of single-photon emission computed tomographic (S.. (context) - Leon, Eisner et al. - 1992
1   Nonisotropic attenuation in SPECT: Phantom tests of quantita.. (context) - Manglos, Jaszczak et al. - 1987
1   Ultra-high-resolution brain SPECT imaging: Simulation result.. (context) - Rogulski, Barber et al. - 1993
1   The influence of left ventricular volume and wall motion on .. (context) - Gewirtz - 1979
1   A rotating and warping projector /backprojector for fan-beam.. (context) - Zeng, Hsieh et al. - 1994
1   SPECT Myocardial Perfusion Scans: A Left Ventricular Defect .. (context) - Boyers - 1991
1   An evaluation of maximum likelihoodexpectation maximization .. (context) - Gilland, Tsui - 1992
1   Significance of regional wall thickening abnormalities relat.. (context) - Gallagher, Kumada et al. - 1980
1   Cardiac emission computed tomography: underestimation of reg.. (context) - Parodi, Schelbert et al. - 1984
1   Fundamentals of 180 o acquisition and reconstruction in SPEC.. (context) - Eisner, Nowak et al. - 1986
1   Quantitative SPECT reconstruction of iodine-123 data (context) - Gilland, Jaszczak et al. - 1991
1   Quantitation in positron emission computed tomography: 5. ph.. (context) - Mazziotta, Phelps et al. - 1981
1   SPECT volume quantitation: Influence of spatial resolution, .. (context) - King, Long et al. - 1991
1   Massively parallel computers for 3D single-photon-emission c.. (context) - Butler, Miller et al. - 1994
1   Gated SPECT with technetium99m -sestamibi for assesment of m.. (context) - Mannting, Morgan-Mannting - 1993
1   An evaluation of the iterative chang algorithm in large fema.. (context) - Di Bella, Eisner et al. - 1995
1   Practical iterative reconstruction methods for quantitative .. (context) - Tsui, Zhao - 1994
1   Fast distributed iterative reconstruction for quantitative S.. (context) - Ju, Frey et al. - 1994
1   Quantitative SPECT brain imaging: Effects of attenuation and.. (context) - Gilland, Jaszczak - 1993
1   Iterative reconstruction methods for nonuniform attenuation .. (context) - Maze, Cloirec et al. - 1993
1   Attenuation artifacts in SPECT: Effect (context) - Di Bella, Eisner et al. - 1995
1   Convolutional image reconstruction for quantitative single p.. (context) - Tanaka, Toyama et al. - 1984
1   The effect of non-uniform attenuation compensation on myocar.. (context) - Manglos, Thomas et al. - 1993
1   Correction for photon attenuation in SPECT: analytical frame.. (context) - Pan, Wong et al. - 1993
1   Weighted backprojection implemented with a non-uniform atten.. (context) - Manglos, Jaszczak et al. - 1988
1   Digital restoration of indium-111 and iodine-123 SPECT image.. (context) - King, Schwinger et al. - 1986
1   An attenuated projector--backprojector for iterative SPECT r.. (context) - Gullberg, Huesman et al. - 1985
1   A simulation of emission and transmission noise propagation .. (context) - Tung, Gullberg - 1993
1   Quantitative reconstruction for myocardial perfusion SPECT: .. (context) - Ye, Liang et al. - 1994
1   Improving the convergence of iterative filtered backprojecti.. (context) - Lalush, Tsui - 1994
1   Heterogeneity of SPECT bull'seyes in normal dogs: Comparison.. (context) - Di Bella, Eisner et al.
1   A practical projector-backprojector modeling attenuation, de.. (context) - Frey, Tsui - 1991
1   A 3D model of non-uniform attenuation and detector response .. (context) - Gilland, Jaszczak et al. - 1994
1   Fourier method for correction of depth-dependent collimator .. (context) - Lewitt, Edholm et al. - 1989
1   Reducing the computational load of iterative SPECT reconstru.. (context) - Glick, Penney et al. - 1994
1   Frequency domain implementation of the threedimensional geom.. (context) - Zeng, Gullberg - 1992
1   Improved lesion detection in SPECT using MLEM reconstruction (context) - Tourassi, Jr et al. - 1991

Documents on the same site (http://wwwrad.med.utah.edu/mirl/dibella/papers/list.html):
Attenuation Artifacts in SPECT: Effect of "Wrap-Around" Lung in.. - Di Bella   (Correct)

Online articles have much greater impact   More about CiteSeer.IST   Add search form to your site   Submit documents   Feedback  

CiteSeer.IST - Copyright Penn State and NEC