Download:
|
by Sunil K. Mishra, Sudheer K. Vemulapalli, Prasant Mohapatra
http://www.ee.iastate.edu/~acar/PUBS/icpp-dcda.ps
Add To MetaCart
Abstract:
Abstract--In this paper, we propose a highly reliable RAID architecture called a Dual-Crosshatch Disk Array. It uses the proposed interleaved 2d-parity scheme, a low overhead triple-erasure correcting parity organization. It is a hybrid approach of RAID-4 and RAID5 with one dedicated parity group and another parity group using block interleaved data and parity. The results obtained from simulations indicate that this architecture possesses extremely high reliability with low overheads, good degraded performance, and acceptable normal-mode performance.
Citations
|
1287
|
The Theory of Error-Correcting Codes
– MacWilliams, Sloane
- 1977
|
|
550
|
The case for redundant arrays of inexpensive disks (RAID
– Patterson, Gibson, et al.
- 1988
|
|
257
|
RAID: High-performance, reliable secondary storage
– Chen, Lee, et al.
- 1994
|
|
170
|
Disk Striping
– Salem, H
- 1986
|
|
124
|
Redundant Disk Arrays: Reliable, Parallel Secondary Storage
– Gibson
- 1992
|
|
58
|
Disk array storage system reliability
– Burkhard, Menon
- 1993
|
|
56
|
Designing disk arrays for high data reliability
– Gibson, Patterson
- 1992
|
|
52
|
Parity logging overcoming the small write problem in redundant disk arrays
– Stodolsky, Gibson, et al.
- 1993
|
|
50
|
EVENODD: An efficient scheme for tolerating double disk failures in RAID architectures
– Blaum, Brady, et al.
- 1995
|
|
47
|
Caching strategies to improve disk system performance
– Karedla, Love, et al.
- 1994
|
|
43
|
The architecture of a fault-tolerant cached RAID controller
– Menon, Cortney
|
|
43
|
An Evaluation of Multiple-Disk I/O Systems
– Reddy, Banerjee
- 1989
|
|
34
|
How reliable is a RAID
– Schulze, Gibson, et al.
- 1989
|
|
29
|
Caching and writeback policies in parallel file systems
– Kotz, Ellis
- 1993
|
|
26
|
Floating Parity and Data Disk Arrays
– Menon, Roche, et al.
- 1993
|
|
25
|
Failure correction techniques for large disk arrays
– Gibson, Hellerstein, et al.
- 1989
|
|
16
|
The performance of parity placements in disk arrays
– LEE, KATZ
- 1993
|
|
15
|
Performance of RAID5 disk arrays with read and write caching
– Menon
- 1994
|
|
10
|
Crosshatch disk array for improved reliability and performance
– Ng
- 1994
|
|
8
|
A study of I/O system organizations
– Reddy
- 1992
|
|
7
|
Design and Evaluation of Gracefully Degradable Disk Arrays
– Reddy, Chandy, et al.
- 1993
|
|
3
|
et al., "RAID: High-Performance, Reliable Secondary Storage
– Chen
- 1994
|
|
3
|
Uniform Parity Group Distribution in Disk Arrays with Multiple Failures
– Ng, Mattson
- 1994
|
|
2
|
Dynamic Parity Grouping for Improved Write Performance
– Yu, Wu, et al.
- 1994
|
|
1
|
et al., "EVENODD: An Optimal Scheme for Tolerating Double Disk Failures
– Blaum
- 1994
|
|
1
|
Performance of RAID-5 Disk Array with Data and Parity Caching
– Mishra, Mohapatra
- 1996
|